CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20
66
5.2. Analog Monitor Output Selecting
The analog monitor output can be switched to monitor various operation and signal statuses.
This switching can be executed from [Control Software] or [RS-232C command send].
Output contents
Terminal
Monitor Board
Signal Name
Power-on
Selection
Signal Description Signal Level (At
Power-on)
2 (Axis 1)
6 (Axis 2)
A2 (Axis 1)
A6 (Axis 2)
Phase A of Encoder Head 1
Phase A of Encoder Head 2
Phase A of encoder after synthesis
* Positional deviation signal 1.5 mV / pulse
3 (Axis 1)
7 (Axis 2)
A3 (Axis 1)
A7 (Axis 2)
Position 0.091 mV / pulse
* Velocity 0.091 mV / pulse / 10
Coarse angle
Fine angle
4 (Axis 1)
8 (Axis 2)
A4 (Axis 1)
A8 (Axis 2)
Phase B of Encoder Head 1
Phase B of Encoder Head 2
Phase B of encoder after synthesis
* Target position 0.091 mV / pulse
The signal level differs between signals. The output magnification can be switched individually.